Brazil Updates Cylinders for Natural Gas in Vehicles Regulatory Framework

Brazil amended its regulatory framework for cylinders for natural gas in vehicles to integrate the "Inmetro in the Palm of your Hand" project, updating conformity requirements for requalification and technical inspection of cylinders

BRAZIL – NATURAL GAS CYLINDERS

Brazil Tightens Rules for Natural Gas Vehicle Cylinders

New digital seals and mandatory inspections are now required for safety and traceability.

No. 314 Ordinance number
29 May 2025 Ordinance passed

What changed

Updated conformity seals are mandated for cylinders to improve traceability.

Requalification is mandatory for cylinders prior to reuse to ensure safety.

Technical inspection is required regularly for natural gas storage cylinders.

Digital integration with the “Inmetro in the Palm of your Hand” project is now required.

Who it affects

Cylinder requalification centers must follow new mandatory procedures for safety.

Vehicle maintenance providers must perform regular technical inspections of gas cylinders.

Cylinder suppliers must apply the updated conformity identification seals.

Key dates

29 May 2025 — Ordinance No. 314 passed.
Brazil — natural gas vehicle cylinder regulations

Compliance Requirements for Cylinders for Natural Gas Vehicles (GNV) Under Brazil’s Updated Regulatory Framework

Brazil has amended its conformity assessment requirements for cylinders used to store Compressed Natural Gas for Vehicles (GNV) to integrate the "Inmetro in the Palm of Your Hand" (Inmetro na Palma da Mão) project. The updates, introduced by Portaria Inmetro nº 409/2026, modify the Selo de Identificação da Conformidade (Conformity Identification Seal) and establish new procedures for requalification, technical inspection, and seal registration. Below is a structured breakdown of the key compliance obligations, deadlines, and procedural changes.

1. Key Changes Introduced by Portaria Inmetro nº 409/2026

The regulation amends multiple existing Portarias Inmetro (231/2021, 108/2022, 58/2022, 436/2021, and 133/2022) to align with the digital authentication project. The primary updates include:

A. New Seal Specifications

  • Dimensions: The Selo de Identificação da Conformidade must measure 30 mm × 40 mm1.
  • Placement: The seal must be affixed to the dome (cúpula) of GNV cylinders2.
  • Authentication: The seal now integrates with the "Inmetro na Palma da Mão" system to prevent counterfeiting1. Suppliers must acquire seals exclusively from:
    • Casa da Moeda do Brasil (Brazilian Mint), or
    • Empresa Brasileira de Correios e Telégrafos (Correios)1.

B. Digital Registration Obligations

  • Mandatory Registration: Starting 1 November 2026, suppliers must register the use of each seal via the "Inmetro na Palma da Mão – Versão Fornecedor" mobile application1.
  • Penalties for Non-Compliance:
    • Failure to register may result in denial of future seal acquisition authorizations1.
    • Additional administrative measures may apply1.

C. Transition Periods and Deadlines

ObligationDeadlineApplicable EntitiesSource
Suppliers must use only the new seal design31 December 2025Manufacturers, importers, service providers (e.g., requalification workshops)1
Suppliers must acquire seals exclusively from Casa da Moeda or CorreiosImmediately (2 July 2026)All suppliers1
Registration of seal use via the app1 November 2026Suppliers (manufacturers, importers, service providers)1
Commercialization of products with old seals (if manufactured/imported before 31 Dec 2025)31 March 2026Manufacturers, importers1
Distributors/commercial establishments must sell only products with new seals30 June 2026Retailers, distributors (excludes manufacturers/importers)1
Stock depletion exception (old seals allowed until exhaustion)No deadlineDistributors/commercial establishments (for seals with Casa da Moeda identification)1

2. Requalification and Technical Inspection Requirements

The updated framework maintains existing requalification and inspection obligations for GNV cylinders but integrates them into the digital system:

A. Requalification of Cylinders

  • Regulatory Basis: Governed by Portaria Inmetro nº 133/20221.
  • Seal Requirements:
    • Requalified cylinders must bear the new seal design (30 mm × 40 mm)1.
    • The seal must be registered in the "Inmetro na Palma da Mão" system1.

B. Technical Inspection of Cylinders

  • Regulatory Basis: Governed by Portaria Inmetro nº 436/20211.
  • Seal Placement: The seal must be affixed to the cylinder dome2.
  • Digital Traceability: Inspection service providers must register seal usage in the app starting 1 November 20261.

3. Compliance Steps for Suppliers and Service Providers

For Manufacturers/Importers:

  1. Acquire New Seals:
    • Purchase seals only from Casa da Moeda or Correios1.
    • Old seals may be used until 31 December 2025 if the product was manufactured/imported before this date1.
  2. Register Seal Usage:
    • Use the "Inmetro na Palma da Mão – Versão Fornecedor" app to log each seal applied starting 1 November 20261.
  3. Phase Out Old Seals:
    • Stop using old seals after 31 December 20251.
    • Commercialize remaining stock with old seals until 31 March 20261.

For Distributors/Retailers:

  • Sell Only New-Seal Products:
    • From 30 June 2026, commercial establishments must sell only products with the updated seal1.
    • Exception: Stocks with old seals (manufactured/imported before 31 Dec 2025) may be sold until exhausted1.

For Requalification/Inspection Service Providers:

  • Affirm New Seals:
    • Apply the 30 mm × 40 mm seal to requalified/inspected cylinders1.
  • Register Seal Usage:
    • Log each seal in the "Inmetro na Palma da Mão" app starting 1 November 20261.

4. Enforcement and Penalties

  • Non-Compliance Risks:
    • Denial of future seal acquisition authorizations for failure to register seal usage1.
    • Administrative sanctions (unspecified in the sources)1.
  • Reporting:
    • Questions or complaints may be directed to selos.dconf@inmetro.gov.br2.

Summary Answer

Brazil’s Portaria Inmetro nº 409/2026 integrates GNV cylinder conformity requirements into the "Inmetro na Palma da Mão" project to combat counterfeiting. Key changes include:

  1. New seal specifications (30 mm × 40 mm, affixed to the cylinder dome)1, 2.
  2. Mandatory digital registration of seal usage via the app starting 1 November 20261.
  3. Transition deadlines:
    • Suppliers must use new seals by 31 December 20251.
    • Distributors must sell only new-seal products by 30 June 20261.
    • Old seals may be commercialized until 31 March 2026 (manufacturers/importers) or until stock exhaustion (distributors)1.
  4. Enforcement: Non-compliance may result in denial of future seal authorizations1.

All obligations apply to manufacturers, importers, service providers (requalification/inspection), and distributors of GNV cylinders under the amended Portarias Inmetro nº 231/2021, 108/2022, 58/2022, 436/2021, and 133/20221, 2.

Sources

  1. members.wto.org — modification / 26 03668 00 x https://members.wto.org/crnattachments/2026/TBT/BRA/modification/26_03668_00_x.pdf
  2. members.wto.org — modification / 26 03669 00 x https://members.wto.org/crnattachments/2026/TBT/BRA/modification/26_03669_00_x.pdf

Create your account