El Salvador has established strict quality limits for special type wastewater discharges into national and private sewer systems, covering industrial, hospital, and chemical effluents, through the Reglamento Técnico Salvadoreño (RTS) 13.05.02:26.
El Salvador Sets Strict Limits for Industrial and Hospital Wastewater
New quality controls for special wastewater discharges into sewer systems.
What changed
Quality limits set for special wastewater discharges into sewer systems.
Industrial effluent covered under new technical regulation RTS 13.05.02:26.
Hospital wastewater included in special wastewater category.
Chemical residuals regulated with specific parameter thresholds.
Who it affects
Industrial facilities must meet quality limits for wastewater discharges.
Hospitals and healthcare providers must comply with special wastewater standards.
Chemical plants must control discharge parameters into sewer systems.
Key dates
Compliance Requirements for Special Type Wastewater Discharges in El Salvador
Direct Answer: El Salvador regulates special type wastewater discharges (industrial, hospital, chemical, and agroindustrial effluents) into national and private sewer systems through Reglamento Técnico Salvadoreño (RTS) 13.05.02:26. Compliance requires adherence to strict permissible limits for 48 parameters, mandatory ANDA authorization, and regular monitoring with penalties for non-compliance1, 2.
Regulation Analysis
1. Scope and Applicability
- Covered Discharges: The RTS applies to special type wastewater (industrial, hospital, chemical, agroindustrial) discharged directly or indirectly into ANDA-administered or private sewer systems1.
- Exclusions: Ordinary domestic wastewater (e.g., from sinks, toilets) is not covered1.
- Indirect Discharges: Includes effluents routed through intermediate systems (e.g., private/industrial sewers) before entering ANDA’s network1.
2. Permissible Limits
The RTS establishes maximum permissible limits for 48 parameters, including:
| Parameter | Unit | Limit | Citation |
|---|---|---|---|
| pH | – | 6.0–9.0 | 1 |
| Temperature | °C | 20–35 | 1 |
| Biochemical Oxygen Demand (BOD₅) | mg/L | 500 | 1 |
| Chemical Oxygen Demand (COD) | mg/L | 1,000 | 1 |
| Oils and Grease | mg/L | 100 | 1 |
| Suspended Solids | mg/L | 300 | 1 |
| Sulfides | mg/L | 25 | 1 |
| Zinc | mg/L | 5 | 1 |
| Cadmium | mg/L | 0.2 | 1 |
| Lead | mg/L | 0.5 | 1 |
- Unlisted Parameters: ANDA may impose additional limits for contaminants not specified in the RTS if they threaten sewer infrastructure or public health1.
- Prohibited Practices:
3. Authorization and Compliance Procedures
A. Mandatory ANDA Authorization
- Requirement: All entities discharging special type wastewater into ANDA’s sewer system must obtain prior authorization1.
- Application Process:
- Submit a formal request (Annex A) to ANDA, including:
B. Monitoring and Reporting
- Sampling Frequency (Table 1 of RTS):
| Discharge Volume (m³/day) | In-Situ Parameters (pH, temperature, etc.) | Lab Parameters (BOD₅, COD, etc.) |
|---|---|---|
| ≤ 10 | Monthly | Annual |
| 10–100 | Weekly | Semiannual |
| > 100 | Daily | Quarterly |
- Sample Types: Simple or composite (collected over ≥3 hours, with aliquots every 30 minutes)1.
- Laboratory Requirements: Analyses must be performed by accredited labs using recognized methodologies1.
- Record Retention: Entities must retain 5 years of monitoring reports1.
C. Inspection and Enforcement
- ANDA’s Authority:
- Penalties: Non-compliance is subject to sanctions under El Salvador’s Environmental Law (Decree No. 233) and General Water Resources Law (Decree No. 253)1.
4. Technical and Operational Requirements
- Sampling Infrastructure:
- Treatment Systems:
- Process Changes: Entities must immediately report modifications that alter effluent characteristics1.
5. Supporting Legislation
The RTS is enforced under:
- Ley del Medio Ambiente (Decree No. 233, 1998) – Article 421.
- Ley General de Recursos Hídricos (Decree No. 253, 2022)1.
- Reglamento Especial de Aguas Residuales y Manejo de Lodos Residuales (current version)1.
Summary Answer
El Salvador’s RTS 13.05.02:26 imposes strict limits on 48 parameters for special type wastewater discharges into sewer systems, including BOD₅ (500 mg/L), COD (1,000 mg/L), and pH (6.0–9.0)1. Compliance requires ANDA authorization, regular monitoring (frequency tied to discharge volume), and unannounced inspections1. Prohibited practices include dilution, stormwater discharge, and unauthorized solids disposal1. Penalties for non-compliance are governed by Decree No. 233 (Environmental Law) and Decree No. 253 (Water Resources Law)1. Entities must retain 5 years of records and report process changes to ANDA1. The RTS is subject to periodic review to align with modern standards2.
Sources
- ↩ WTO SPS notification 26-02816 — El Salvador https://members.wto.org/crnattachments/2026/SPS/SLV/26_02816_00_s.pdf
- ↩ WTO TBT notification 26-01725 — El Salvador https://members.wto.org/crnattachments/2026/TBT/SLV/26_01725_00_s.pdf